• automated external defibrillator,manual external defibrillator,defibrillator pacer function

DEFI Xpress 8 Inch Screen Manual&Automated External Defibrillator With Pacer Function

Defibrillation Monitor is a safe, easy to use defibrillation and monitoring device. The system is an extremely flexible device that integrates manual defibrillation mode, monitoring mode and AED mode.

  • Product Description
  • Technical Parameters
  • Video

8 Inch Screen Manual&Automated External Defibrillator With Pacer Function Features:

1. With manual defibrillation, automatic external defibrillation (AED), ECG monitoring and other functions, is a professional dual-phase defibrillation monitor, suitable for hospitals and clinics;

2. 8-inch screen showing HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

3. Automatic analysis of external defibrillation, can automatically select energy, provide screen display and voice prompt.

4. Built-in battery, can be recharged multiple times.

5. Defibrillation output waveform: biphase waveform

6. 50mm thermal printer provides defibrillation record.

7. The maximum energy in manual mode is 360J

8. 3-lead / 5-lead ECG monitoring, displayed on the screen, providing alarm tips.

9. Optional cardiac pacing function.

automated external defibrillator,manual external defibrillator,defibrillator pacer function

Specification pacer (Optional)
Type VVI
Pulse Type rectangular,constant current
Pulse Amplitude 0 to 180 mA±10% or 5 mA (whichever is greater).
Pacing Rate Variable from 30 ppm to 180 ppm +1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode (MFE)Pads multipurpose defibillation/pacing electrodes
Pause Pacing pulse frequency reduced by a factor of 4 when activated.
Refractory Period NC(VVI demand do not have this specification)
Pulse Width (20+ 1.5 ms)
Output Protection Fully defibrillator protected and isolated
Specification EtCO2 (Optional)
Type of sensor By-pass
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40 °C to 70°C,<90% RH, non-condensing
Operating conditions 5°C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5V±5% (max ripple 200 mVp-p)
TDP Typical value 120mA Excursion calibration typical value 280mA
Range 0-19.7% (0-150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0-40mmHg±2mmHg
41 – 70 mmHg±5% of reading
71 – 100 mmHg±8% of reading
101 – 150 mmHg±10% of reading
Respiratory rate 2-150 BPM
Respiratory rate measurement accuracy 1% ±1BPM
Specification NIBP (Optional)
Measurement unti: mmHg/kPa
Measurement Range: Adult:10~270 mmHg/kPa
Pediatric: 10~200 mmHg/kPa
Neonatal: 10~135 mmHg/kPa
Resolution 1 mmHg
Accuracy: Maximum mean error:5 mmHg
Maximum standard deviation:8 mmHg
Type of sensor By-pass
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40°C to 70°C, <90% RH, non-condensing
Operating conditions 5°C to 50°C, 10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5V±5% (max ripple 200 mVp-p)
TDP Typical value 120mA Excursion calibration typical value 280mA
Range 0-19.7% (0-150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0-40mmHg±2mmHg
41 – 70 mmHg±5% of reading
71 – 100 mmHg±8% of reading
101 – 150 mmHg±10% of reading
Respiratory rate 2-150 BPM
Respiratory rate measurement accuracy 1%±1BPM
Specification SPO2 Moudle (Optional)
Measurement Range: 30 ~ 100% ,±2% between 80% ~ 90%,Others +5%
Alarm Range User set high limit and low limit
Alarm Accuracy ±10 within setting values.
Alarm Time Accuracy Less than 12 sec.